Sunday, April 21, 2019
Electroencephalography Lab Report Example | Topics and Well Written Essays - 2000 words
Electroencephalography - Lab Report ExampleOn the first look, encephalogram statistics is seen as noisy signal, unstructured, a ND non-stationary. However, the advanced signal processing methods are used in separating different brain drift components. The components are associated with various brain functions and areas (Walter, 2001). The present research is focused on the correlation discovery amid the specific brain tasks pattern to mental health, sleep phases, and emotional states. In a medical doting, EEG is mainly used for diagnosing neurological disorders like the patients consciousness, and epilepsy during the surgical procedures. Additionally, it is shown that signals of EEG are used as inputs to control for the other systems like the computer interface. This is important during spinal cord injury in restoring function. The science lab uses the Bio Radion in detecting the electrical activity in the cerebral cortex and apply some radical analysis methods in interpreting the entropy. Retrieved on 29th October 2013 https//www.google.co.ke/search?q=the+human+brain+main+regions&newwindow=1&client=firefox-beta&hs=3vm&rls=org.mozilla Methods and Equipment required CleveLabs Kit CleveLabs Course Software Seven Gold Cup Software semiconductive Gel Wipes, Gauze, and Cotton balls MS Excel During the lab session the four EEG channels were recorded. The ii channels will be in from the frontal region and the other channels will be from the occipital section. The Clevelab software is included when setting up the movie before starting the proveal set up in the laboratory process. 1. In performing the experiment, the subjects should have short whisker. The subjects should have free hair gel scalp. The experiment also requires 7 golden cup electrodes. The electrodes will be positioned at 01 and 02, FP1, and FP2 in measuring the EEG, on every mastoid and FPZ from the ground. The processes of mastoid are the structures that are bony like that canister be felt behind the ears. Before the application of electrodes to the subject it is crucial to clean and prepare the sites of electrodes. 2. At this constitute, the electrode attachment is carried out. Fill the electrode generously with the given gel to fill the cup (Electroencephalography and clinical neurophysiology, 2007). Slide the gold cup electrode with the gel into the pad and then push the hair sideways and place electrode on the subjects dot at O1. Repeat the other electrode at the locations. The placement of electrodes at point O1 and O2 is shown below. Retrieved on 29th October 2013 http//www.upstate.edu/cdb/ knowledge/grossanat/hnsklattb5.shtml 3. Connect the leads of gold cups and jumpers to transmit inputs 1, 2, 3, 4, and the ground by using the outlined figure as the reference (Cohn, 2009). The heads left has now been symmetrically to the right side from the top down view. As shown in the diagram below Retrieved on 29th October 2013 http//glneurotech.com/bioradio/bioradio-w ireless-physiological-monitor/ Procedure and collection of data The procedure of this experiment involves the calibration, data recording, and analysis of data. The setup entails turning the computer on and plug the BIORADIO equipment followed electrode positioning. The second stage is calibration. The stage ensures that the electrodes are good places and the relaxation of the subject. The data that is calibrated is checked to make sure that they are the same. Consequently, the data recording is performed when
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment
Note: Only a member of this blog may post a comment.